@ -18,6 +18,13 @@ homeassistant:
|
|||
cover.*:
|
||||
half_position: 25
|
||||
|
||||
dimmer:
|
||||
|
||||
#logger:
|
||||
# default: info
|
||||
# logs:
|
||||
# xknx.telegram: debug
|
||||
# xknx.knx: debug
|
||||
|
||||
# Sensors
|
||||
#sensor:
|
||||
|
@ -25,23 +32,41 @@ homeassistant:
|
|||
# - platform: yr
|
||||
|
||||
# Text to speech
|
||||
#tts:
|
||||
## - platform: google_translate
|
||||
# language: 'de'
|
||||
# base_url: http://192.168.178.73:8123
|
||||
tts:
|
||||
- platform: google_translate
|
||||
- platform: watson_tts
|
||||
watson_apikey: X_tnnoaZGOwxZlqUn07wkD2G-0vaaAuOw6I6d_6jpCf7
|
||||
watson_url: https://gateway-lon.watsonplatform.net/text-to-speech/api
|
||||
voice: de-DE_BirgitVoice
|
||||
output_format: audio/flac;rate=44100
|
||||
|
||||
knx:
|
||||
rate_limit: 20
|
||||
tunneling:
|
||||
host: 192.168.178.80 # knxd to work together with old home automation server
|
||||
host: server # knxd to work together with old home automation server
|
||||
#host: 192.168.178.65 # network bridge
|
||||
port: 3671
|
||||
local_ip: 192.168.178.74
|
||||
local_ip: 192.168.178.73
|
||||
|
||||
fhem:
|
||||
host: 192.168.178.80
|
||||
host: server
|
||||
port: 7072
|
||||
cul_device_name: CUL_HM
|
||||
|
||||
|
||||
media_player:
|
||||
- platform: squeezebox
|
||||
host: server
|
||||
- platform: denonavr
|
||||
host: avreceiver
|
||||
|
||||
|
||||
|
||||
|
||||
|
||||
group: !include groups.yaml
|
||||
automation: !include automations.yaml
|
||||
script: !include scripts.yaml
|
||||
|
|
|
@ -0,0 +1,70 @@
|
|||
""" Service to increase/decrease light brightness"""
|
||||
import logging
|
||||
import voluptuous as vol
|
||||
|
||||
from homeassistant.components.light import ATTR_BRIGHTNESS, DOMAIN as LIGHT_DOMAIN, ATTR_TRANSITION
|
||||
from homeassistant.const import SERVICE_TURN_ON, ATTR_ENTITY_ID
|
||||
|
||||
# The domain of your component. Should be equal to the name of your component.
|
||||
from homeassistant.helpers.service import async_extract_entity_ids
|
||||
|
||||
DOMAIN = "dimmer"
|
||||
|
||||
# List of component names (string) your component depends upon.
|
||||
# We depend on group because group will be loaded after all the components that
|
||||
# initialize devices have been setup.
|
||||
DEPENDENCIES = ['group', 'light']
|
||||
|
||||
# Name of the service that we expose.
|
||||
SERVICE_DIM = 'dim'
|
||||
|
||||
# Shortcut for the logger
|
||||
_LOGGER = logging.getLogger(__name__)
|
||||
|
||||
# Validate that all required config options are given.
|
||||
CONFIG_SCHEMA = vol.Schema({
|
||||
DOMAIN: vol.Schema({})
|
||||
}, extra=vol.ALLOW_EXTRA)
|
||||
|
||||
|
||||
async def async_setup(hass, config):
|
||||
"""Setup example component."""
|
||||
|
||||
async def async_dim_service(service):
|
||||
params = service.data.copy()
|
||||
|
||||
entity_ids = await async_extract_entity_ids(hass, service, expand_group=True)
|
||||
|
||||
offset = params.get('offset', None)
|
||||
factor = params.get('factor', None)
|
||||
min_brightness = params.get('min_brightness', 6)
|
||||
|
||||
transition = params.get(ATTR_TRANSITION, None)
|
||||
|
||||
if factor is None and offset is None:
|
||||
offset = 50
|
||||
|
||||
assert not (factor is not None and offset is not None)
|
||||
|
||||
def clip_value(level):
|
||||
level = int(level)
|
||||
if level < min_brightness:
|
||||
return min_brightness
|
||||
if level > 255:
|
||||
return 255
|
||||
return level
|
||||
|
||||
for entity_id in entity_ids:
|
||||
brightness = hass.states.get(entity_id).attributes.get('brightness', 0)
|
||||
if factor is not None:
|
||||
data = {ATTR_BRIGHTNESS: clip_value(brightness * factor)}
|
||||
if offset is not None:
|
||||
data = {ATTR_BRIGHTNESS: clip_value(brightness + offset)}
|
||||
data[ATTR_ENTITY_ID] = entity_id
|
||||
if transition:
|
||||
data[ATTR_TRANSITION] = transition
|
||||
await hass.services.async_call(LIGHT_DOMAIN, SERVICE_TURN_ON, data)
|
||||
|
||||
hass.services.async_register(DOMAIN, SERVICE_DIM, async_dim_service)
|
||||
|
||||
return True
|
|
@ -0,0 +1,17 @@
|
|||
|
||||
dim:
|
||||
description: Increases or decreases brightness of lights
|
||||
fields:
|
||||
entity_id:
|
||||
description: Name(s) of entities or groups
|
||||
example: 'light.living_room'
|
||||
offset:
|
||||
description: New light value is old value plus this offset (full brightness is 255).
|
||||
Can be negative to decrease brightness
|
||||
example: 30
|
||||
factor:
|
||||
description: Factor to multiply old light value with. Use either offset or factor, not both!
|
||||
example: 1.3
|
||||
transition:
|
||||
description: transition time in seconds
|
||||
example: 1
|
|
@ -48,6 +48,10 @@ class FhemConnection:
|
|||
|
||||
def register_device(self, id, d):
|
||||
self._devices[id].append(d)
|
||||
if self._writer:
|
||||
self._writer.writelines([
|
||||
"displayattr .*\n".encode(),
|
||||
])
|
||||
|
||||
async def _update_all_devices(self):
|
||||
for device_list in self._devices.values():
|
||||
|
@ -80,6 +84,9 @@ class FhemConnection:
|
|||
])
|
||||
while self._run:
|
||||
line = await reader.readline()
|
||||
if not line:
|
||||
_LOGGER.warning("FHEM disconnected: {}".format(line))
|
||||
raise OSError("Disconnect")
|
||||
line = line.decode()
|
||||
_LOGGER.debug("FHEM received line: {}".format(line))
|
||||
await self._process_line(line)
|
||||
|
@ -93,7 +100,7 @@ class FhemConnection:
|
|||
self.connected = False
|
||||
await self._update_all_devices()
|
||||
await asyncio.sleep(self.reconnect_time)
|
||||
self.reconnect_time = min(2 * self.reconnect_time, self.reconnect_time)
|
||||
self.reconnect_time = min(2 * self.reconnect_time, self.reconnect_time_max)
|
||||
self.hass.loop.create_task(self._connection())
|
||||
|
||||
async def _process_line(self, line):
|
|
@ -88,7 +88,8 @@ class FhemCover(CoverDevice):
|
|||
_, new_motor_state, new_position = line.split(':')
|
||||
new_position = new_position.strip().lower()
|
||||
new_motor_state = new_motor_state.strip().lower()
|
||||
assert new_motor_state == 'stop' or new_motor_state == 'up' or new_motor_state == 'down'
|
||||
assert new_motor_state == 'stop' or new_motor_state == 'up' or new_motor_state == 'down', \
|
||||
'Unknown motor state ' + new_motor_state
|
||||
if new_motor_state == 'stop':
|
||||
if new_position == 'on':
|
||||
self._position = 100
|
|
@ -73,22 +73,19 @@ class FhemLight(Light):
|
|||
return None
|
||||
|
||||
async def async_turn_on(self, **kwargs):
|
||||
brightness = kwargs.get(ATTR_BRIGHTNESS, self.brightness)
|
||||
transition_time = kwargs.get(ATTR_TRANSITION, None)
|
||||
brightness = kwargs.get(ATTR_BRIGHTNESS, None)
|
||||
transition_time = kwargs.get(ATTR_TRANSITION, 0.5)
|
||||
|
||||
if brightness is None:
|
||||
brightness = 255
|
||||
|
||||
if self._dimmer:
|
||||
if transition_time is not None:
|
||||
# zero in the middle is the time until light is switched off,
|
||||
# which is disabled here when passing 0
|
||||
self.connection.fhem_set(self._ids[0], brightness / 255 * 100, 0, transition_time)
|
||||
else:
|
||||
self.connection.fhem_set(self._ids[0], brightness / 255 * 100)
|
||||
self.connection.fhem_set(self._ids[0], int(brightness / 255 * 100), 0, transition_time)
|
||||
else:
|
||||
self.connection.fhem_set(self._ids[0], 'on')
|
||||
self._brightness = brightness
|
||||
await self.async_update_ha_state()
|
||||
|
||||
async def async_turn_off(self, **kwargs):
|
||||
self.connection.fhem_set(self._ids[0], 'off')
|
38
todo
38
todo
|
@ -1,44 +1,28 @@
|
|||
- add fhem devices [ok]
|
||||
- generate config [ok]
|
||||
- test config [ok]
|
||||
|
||||
- add shutters [ok]
|
||||
- add sensors [ok]
|
||||
- check out read addresses [ok]
|
||||
- in bus monitor [ok]
|
||||
- KNX config files -> add to git [ok]
|
||||
|
||||
|
||||
- configure frontend [ok]
|
||||
- add scenes
|
||||
- add brighter/darker action (service!)
|
||||
- fix door light [ok]
|
||||
- check out motion detectors in frontend
|
||||
- check out shutters in frontend
|
||||
|
||||
Frontend:
|
||||
- change cover state card for half open [ok]
|
||||
|
||||
- add scenes
|
||||
|
||||
LIRC connection:
|
||||
-
|
||||
|
||||
Squeezebox:
|
||||
- standard setup
|
||||
- radio service
|
||||
|
||||
FHEM:
|
||||
- reconnection & message reporting code!
|
||||
- add FHEM shutters [ok]
|
||||
- motion detector [ok]
|
||||
- service for device stuff (up/down time, auto-off stuff)
|
||||
- check FHEM reconnection
|
||||
- what happens when FHEM stops?
|
||||
- check FHEM reconnection [ok]
|
||||
- what happens when FHEM stops? [ok]
|
||||
- what happens when stick is pulled?
|
||||
|
||||
Owntracks
|
||||
- try basic owntracks setup
|
||||
|
||||
|
||||
Other:
|
||||
- grouped motion sensors (last motion where and when)
|
||||
- media player card:
|
||||
https://github.com/kalkih/mini-media-player
|
||||
|
||||
|
||||
|
||||
2019-06-03 19:20:46 WARNING (MainThread) [xknx.log] Could not read value of <Light name="Haustür Licht NW" switch="GroupAddress("0/0/3")/GroupAddress("0/0/4")/None/None" /> 0/0/4
|
||||
2019-06-03 19:20:48 WARNING (MainThread) [xknx.log] Could not read value of <Light name="Haustür Licht" switch="GroupAddress("0/0/1")/GroupAddress("0/0/2")/None/None" /> 0/0/2
|
||||
|
||||
|
|